2000 LPH RO Plant
₹250,000.00
Product Details:
Minimum Order Quantity | 1 Unit |
Plant Application | Industrial RO Plant |
Design | Standard |
Installation/Civil Work | Included |
Antiscalant Dosing Pump | Yes |
Automatic Grade | Automatic |
RO Capacity (Liter/hour) | 2000 (Liter/hour) |
Number of Membranes in RO | 2 |
Material of Construction Skid | Stainless Steel |
Voltage Requirement | 440 V |
Description
The Industrial Reverse Osmosis Plants are manufactured as per the client’s technical specifications and usage. This 2000 LPH RO Plant can cater to the need for 2000-3000 employees/students every day. We design the plants in accordance with the standards & requirements of a particular industry or business.
The commercial RO provides high output and a long life span than the domestic RO purifiers. At Soni Enterprises we manufactured the high-quality RO system with state of art technologies.
We understand the requirement from clients and provide a customized solution with different industry requirements. Furthermore, we always believe in the customer delight model and provide our best in terms of our product and after-sales services.
Main Features 2000 LPH RO Plant:
Low Energy Consumption – Energy is a very costly resource and also has a high impact on the environment hence We have designed the water plants to consume less energy than other RO water plants. Since we use the best quality electrical components and pumps.
Durable Product – We believe in providing the best quality products. We ensure high-quality standards at every stage of production and at the RO Plant Design stage hence this 2000 LPH RO Plant is a durable product and requires very little maintenance.
Warranty – We provide a year full warranty to make your you and your team do not suffer or waste your time to figure out how to get it service or repair.
Non–Corrosive – The skid provides with this 2000 LPH RO system is made up of stainless steel. So the product is corrosion free unlike other brands with MS or powder-coated frames.
Mineral and Alkaline – Being the health of our customers at our topmost priority we provide alkaline water purifiers with mineral technology without adding chemicals. Hence the water purifier generates water that is healthy as well as pure.
Installation and Services – We provide free installation for our RO water plants. Our products are having a year’s warranty so you can order without any hesitation.
Special Features:
- Energy-efficient design so less power consumption
- low wastage hence become environment-friendly
- We design the plant according to standards hence require low maintenance
Main Usage:
- For Industrial and business purposes like corporate offices, Manufacturing plants, Pharmaceutical purposes also.
- Commercial buildings and malls etc.
2000 LPH RO Plant Price:
Here we have offered the very best cost for RO water plant 500 LPH price and you can compare the RO plant price in India, further you can contact us for more details and RO Plant Quotation. We provide a quotation within 2 hours, please give us a call or send us your details.
Detailed Specification 2000 LPH RO Plant:
RAW WATER & FLUSHING PUMP | 02 No. |
Moc
Voltage Make |
( CI Centrifugal)
440/3-phase/50hz CRI/Kirloshkkar/ Equiv. |
MULTIGRADE FILTER (MGF) | 01 No |
MOC
Size Flow Controls Make |
FRP
16”x64” MPV 1” Pentair and Eqv. |
ACTIVATED CARBON FILTER (ACF) | 01 No. |
MOC
Size Flow Controls Media Make |
FRP
16”x64” MPV 1” Activated Carbon Pentair and Eqv. |
ANTISCALANT DOSING PUMP | 01 No. |
Moc
Make Type |
PP
E-dose Equiv. Diaphragm |
MICRON FILTER | 02 No. |
Moc
Size Cartridge Micron Rating |
PP
20” Jumbo 20” String Wound 05 Micron |
MEMBRANE HOUSING | 02 Nos. |
Moc
Make Testing Construction |
FRP Food Grade
Altima/ Aventura/ equv. Pressure 500 psi End Port Type |
RO MEMBRANES | 02 Nos. |
Type of Membrane
Size Make |
Thin Film Composite
8” Dia 40” Length Dow Equiv. |
HIGH-PRESSURE PUMP | 01 No. |
Type of Pump Make |
Centrifugal Multistage Vertical
CRI/Kirloskar/ Equiv. |
CONTROL INSTRUMENTS | |
Flow Meter
Pressure Gauge LPS, HPS, TDS Meter |
– 4 Nos.
– 4 Unit – 1 Unit Each |
CONTROL PANEL | 01 No. |
SKID | SS |
DOSING TANK | 01 Nos. |
PIPING | High-Pressure pipeline |
Good Know About Reverse Osmosis and RO Plant
A. About Reverse Osmosis :
1. Osmosis:
In the Osmosis a weaker saline (e.g. water) solution will tend to migrate to strong saline (salts) solution. It occurs naturally and doesn’t require any external force.
For example, when you put resins in the water after 3-4 hours they swallow because the water inserts into the resin from the resin membrane.
2. Reverse Osmosis
Reverse Osmosis is just the reverse of Osmosis and requires external force and the water flow from a high concentration (Inlet water) to low concentration (treated water). A reverse osmosis membrane is a semi-permeable membrane that allows the passage of water molecules but not the majority of dissolved solids.
3. Reverse Osmosis principle:
It works by providing a high pump to extend the pressure on the salt side of the water and force the water across the semi-permeable RO membrane, It reduce most (around 95% to 99%) of TDS (total dissolved solids) behind within the reject stream.
4. What is Permeate and Rejet Water
The desalinated water that’s demineralized or deionized, is named permeate (or product) water. The water stream that carries the concentrated contaminants that didn’t undergo the RO membrane is named the reject (or concentrate) stream
5. How Much Pressure Require:
The quantity of pressure required depends on the salt concentration of the feed water. The more concentrated the feed water, the more pressure is required to pass through the permeate or pure water.
6. Size of RO Membrane :
RO membrane rejects the impurities on the basis of their sizes and ions. The size of the RO Membrane is 0.0001micron or 10-10 meters.
B. Types of contaminants that Reverse Osmosis remove from water?
As we have said earlier that Reverse Osmosis is capable of removing up to 99% of the dissolved salts (TDS), suspended particles, pesticides, organic impurities, bacteria, and viruses from the feed water.
Although an RO system is not reliable for 100% removal of bacteria and viruses It can be provided with UV or UF membrane.
Reverse Osmosis Plant Design Calculations
Whenever an RO Plant is designed it is mainly based on various factors. An RO system has instrumentation that displays quality, water flow as well as the pressure inside the RO membrane, and sometimes other data like temperature and hours of operation.
So to ensure that the RO system function as per our requirement or clients requirement, the following parameters are required to cross-check.
- Inlet Water TDS & Water Hardness
- Water Silica and Fluoride content
- Inlet Water pressure
- Membrane pressure
- Inlet Water conductivity
- Permeate conductivity
- Feed flow
- Permeate flow
- Temperature etc.
You must be logged in to post a review.
Reviews
There are no reviews yet.